General
The RP-2002 is a six-zone FACP for single and dual hazard
agent releasing applications. The RP-2002 provides reliable
fire detection, signaling and protection for commercial, industrial and institutional buildings requiring agent-based releasing.
The RP-2002 is compatible with System Sensor’s i3 detectors
which are conventional smoke detectors that can transmit a
maintenance trouble signal to the FACP indicating the need for
cleaning and a supervisory ‘freeze’ signal when the ambient
temperature falls below the detector rating of approximately
45°F (7.22°C). In addition, the control panel is compatible with
conventional input devices such as two-wire smoke detectors,
four-wire smoke detectors, pull stations, waterflow devices,
tamper switches and other normally-open contact devices.
Refer to the Notifier Device Compatibility Document for a complete listing of compatible devices.
Four outputs are programmable as NACs (Notification Appliance Circuits) or releasing circuits. Three programmable
Form-C relays (factory programmed for Alarm, Trouble and
Supervisory) and 24 VDC special application resettable and
non-resettable power outputs are also included on the main
circuit board. The RP-2002 supervises all wiring, AC voltage,
battery charger and battery level.
Activation of a compatible smoke detector or any normallyopen fire alarm initiating device will activate audible and visual
signaling devices, illuminate an indicator, display alarm information on the panel’s LCD, sound the piezo sounder at the
FACP, activate the FACP alarm relay and operate an optional
module used to notify a remote station or initiate an auxiliary
control function.
The RP-2002E offers the same features as the RP-2002 but
allows connection to 220/240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 110/
120 VAC and 220/240 VAC versions of the panels.
Features
• Listed to UL Standard 864, 9th edition.
• FM Approved.
• Designed for agent releasing standards NFPA 12, 12A,
12B, and 2001.
• Meets International Building Code (IBC) seismic requirements.
• Disable/Enable control per input zone and output zone.
• Extensive transient protection.
• Dual hazard operation.
• Adjustable pre-discharge, discharge and waterflow delay
timers.
• Cross-zone (double-interlock) capability.
• Six programmable Style B (Class B) IDCs (Initiating Device
Circuit).
• System Sensor i3 series detector compatible.
• Four programmable Style Y (Class B) output circuits – (special application power).
• Strobe synchronization:
– System Sensor
– Wheelock
– Gentex
– Faraday
– Amseco
• Three programmable Form-C relays.
• 7.0 amps total 24 VDC output current.
• Resettable and non-resettable output power.
• Built-in Programmer.
• ANN-BUS connector for communication with optional
devices (up to 8 total of any of the following):
– N-ANN-80 Remote LCD Annunciator
– N-ANN-I/O LED Driver
– N-ANN-S/PG Printer Modules
– N-ANN-RLY Relay Module
– N-ANN-LED Annunciator Module
• 80-character LCD display (backlit).
• Real-time clock/calendar with daylight savings time control.
• History log with 256 event storage.
• Piezo sounder for alarm, trouble and supervisory.
• 24 volt operation.
• Low AC voltage sense.
• Outputs Programmable for:
– Releasing Circuits or NACS
• NACs programmable for:
– Silence Inhibit
– Auto-Silence
– Strobe Synchronization
– Selective Silence (horn-strobe mute)
– Temporal or Steady Signal
– Silenceable or Non-silenceable
– Release Stage Sounder